To find out whether your solar panels are underperforming, compare this month’s generation with the same month last year, allow for the weather, and then check it against what a system like yours should make. Most “drops” turn out to be the season or a dull spell. Here is how to tell the difference.
1. Find your numbers
Your inverter app, or the display on the inverter itself, records generation by day, month and year. Many systems also have a separate generation meter. Write down the monthly totals, or export them if the app allows.
2. Compare like with like
Solar output changes enormously through the year, so last month tells you nothing about this month.
Government figures show how big the swing is. In its latest analysis of hundreds of thousands of UK installations, the Department for Energy Security and Net Zero found that solar systems worked at 13.6% of their full capacity in spring 2024, and at 4.7% in the darkest quarter of the year. That is nearly three times as much in spring as in winter, from the same panels.
So always compare June with last June, and November with last November.
3. Allow for the weather
Even the same month differs from year to year. The same government analysis found that typical solar output across the UK fell to its lowest on record in 2024/25, and gives the reason: “Average sun hours in 2024/25 were down on the previous year and were at their lowest since 2012/13.”
In other words, every system in the country had a poor year, clean or dirty. A few percent down on last year, in a duller month, is weather. Look for a drop that is larger than that, or one that persists through bright spells.
4. Check against what it should make
Two free yardsticks:
- Your handover paperwork. A system installed under the MCS scheme comes with an estimate of its yearly generation. It is an estimate, not a guarantee, but you should be somewhere near it over a full year.
- PVGIS. The European Commission’s PVGIS tool is free and needs no account. Enter your location, the size of your system in kWp, and the slope and direction of your roof, and it estimates the energy you should generate each month.
If a full year comes in well under both, something is holding the system back.
5. Work out the cause
- Shade that wasn’t there before. A tree that has grown, a neighbour’s extension, a new aerial. Watch where shadows fall at midday.
- Dirt. Look from the ground with binoculars or your phone camera. Droppings, a green edge or a grey film are easy to spot. Our guide to whether panels need cleaning covers what to look for, and bird droppings explains why a small patch can matter.
- A fault. An error light or message on the inverter, a string showing zero, or one day’s output suddenly halving. This is a job for an MCS-certified installer, not a cleaner.
- Age. Panels lose a little output every year. It is slow, and it does not explain a sudden change.
When it is dirt, and when it isn’t
Dirt tends to show as a gradual slide over months that a clean reverses. A fault shows as a step change, often overnight. Shade shows at particular times of day or year.
If you can see the dirt, a clean is the cheap thing to try first. If the glass looks clear and the numbers are still low, call your installer before you call a cleaner. We would tell you the same if you asked us.
If your panels are in Kent and they do need a clean, you can book online at a fixed price.